How can I replace a hard drive and rebuild a RAID array in the LinkStation? (LS-WVL, LS-WXL)

  • 公開 2011年10月19日 13時24分
  • 更新 2014年7月30日 16時20分

How can I replace a hard drive and rebuild a RAID array in the LinkStation? (LS-WVL, LS-WXL)

Follow the steps below to replace a failed hard drive.

If a drive in your LinkStation fails, identify the failed drive from Settings(*) by navigating to [System] – [Storage]. Replace it with a Buffalo Technology OP-HD series drive of the same capacity, available from www.buffalotech.com.

 

How to Open Settings

 

 

Drives in RAID 1

When the RAID is rebuilt, your data is copied to the new drive. No data is lost in this case.

If the other drive fails before your new drive is installed, all data on the array will be lost.

 

Drives in RAID 0 or normal mode

All data on the failed drive and any array that it was part of is lost.

 

 

1.

Shut down the LinkStation by setting the switch to the Off position, then remove all cables.

Image

 

2.

Remove the front cover.

Image

 

3.

Pull out the tab above the failed drive while pressing the release below the drive.

The tab will slide out approximately 2 cm (1 inch).

Image

 

4.

Remove the failed drive.

Image

 

5.

Insert the new drive until it clicks.

Image

 

6.

Replace the front cover.

Image

 

7.

Reconnect all cables.

Image

 

8.

Power on the LinkStation.

Image

 

9.

If your LinkStation is in RAID 0 or RAID 1, navigate to [System] - [Storage] - [RAID Array] in Settings. Highlight the RAID array, then click [Rebuild RAID array].

Image

Note:
If the LinkStation is in normal mode, format the new drive in [System] - [Storage].

 

 

The LinkStation is now ready to use.

 

 

 